{"product_id":"fluke-networks-certified-cabling-test-technician-cctt-workshop","title":"Fluke Networks Certified Cabling Test Technician (CCTT) Workshop","description":"\u003cp\u003e\u003cstrong\u003eDate\u003c\/strong\u003e: \u003cstrong\u003e6 \u0026amp; 7 July 2026\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTime\u003c\/strong\u003e: \u003cstrong\u003e9:00am - 6:00pm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e: \u003cstrong\u003eCETM Campus\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"cvGsUA direction-ltr align-justify para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eThe Fluke Networks Certified Cabling Test Technician™ (CCTT) is a two-day training and certification program that covers the standards, techniques, documentation and troubleshooting of copper and fiber network infrastructure, with extensive hands-on exercises using the Fluke Networks Versiv Cabling Certification System.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"cvGsUA direction-ltr align-justify para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eIt is uniquely designed for network cabling contractors and enterprise network owners who currently own or anticipate purchasing Versiv \/ DSX series cable certification equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWHY SHOULD YOU SIGN-UP?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eThe CCTT course provides expert level training on the DSX Cable Analyzer series. Investing in the Fluke Networks Certified Cabling Test Technician program will not only improve installation skills, but also your effectiveness and productivity on the job – testing, certifying and troubleshooting cabling systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOURSE OUTLINE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eDay 1 - DSX Cable Analyzer Testing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\n\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eVersiv introduction and common settings\u003c\/span\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003e \u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eExporting configuration and results\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003eCopper test limits\/standards\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003eAdapter types\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003eConfiguring for a twist pair test\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003eMaking a measurement and reviewing the result\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003eNew test parameters DC Resistance Unbalance, TCL, ELTCTL.\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003eDSX diagnostics HDTDX and HDTDR\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003ePatch cord certification\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003eAlien Crosstalk\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eDay 2 - CertiFiber Pro and OptiFiber Pro Testing\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\n\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eBasic fiber theory\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\n\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e Encircled Flux\u003c\/span\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eConfiguring the CertiFiber Pro\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\n\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eFiber inspection\u003c\/span\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\n\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eAutomated analysis\u003c\/span\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eSetting a reference for a LC to LC duplex link\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003eNew test parameters DC Resistance Unbalance, TCL, ELTCTL.\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\n\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eCreating a custom test limit\u003c\/span\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eISO\/IEC 14763-3\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eUnderstanding how the different connector losses differ from other standards\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eSetting a reference for a simplex link. SC\/APC to SC\/APC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003eOTDR theory\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003eConfiguring the OptiFiber Pro\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003eTrace analysis\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"cvGsUA direction-ltr align-start para-style-body\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003eLinkWare results management\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none white-space-prewrap\"\u003e\u003cem\u003e\u003cstrong\u003eExamination \u0026amp; Certificate:\u003c\/strong\u003e\u003c\/em\u003e The course includes a multiple-choice exam, which will take place online once the course material has been delivered on each day. Results will be announced automatically after completing it online. Signed certificate with a 2-years validity will be issued to those attendees who passed each exam (and will be deemed as successfully completing the course).\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"CETM Campus","offers":[{"title":"Default Title","offer_id":46843567833341,"sku":"CETM FNET CCTT Course","price":900.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/7521\/4589\/files\/FNET-CCTT_Course_product_card.png?v=1762314849","url":"https:\/\/cetmcampus.com\/products\/fluke-networks-certified-cabling-test-technician-cctt-workshop","provider":"CETM Campus","version":"1.0","type":"link"}